loader image
We Understand...
To Undertake...

IRIS INSPECTION
Internal Rotary Inspection Services

IRIS 9000+ Probes

The IRIS probes operate in pulse-echo mode to measure wall thickness, material loss, and defect orientation within the range of 8.6mm (0.34 in.) to 82.6mm (3.25 in.) ID.

 

COMPLETE PROBE CABLE ASSEMBLIES

Complete probe cable assemblies including; turbine with mirror, centering device/main body tube, custom transducer, probe cables, adapter/flood tube.

The following components are necessary to “build” a complete IRIS probe. These components are interchangeable and should be chosen according to the tube dimensions.
  • Turbine
  • Ultrasound transducer
  • Centering device
  • Probe cable
  • Tube flooding adapter
Part NumberTube Range IDDescription
0080018.6mm (.34”) – 12.2mm (.5”)8.6mm probe assembly complete: 8.6mm (.34″) diameter turbine with mirror, main body tube, 15 MHz, 5.4mm (.21″) diameter, focused at 19.05mm (.75″), 15.24m (50′) umbilical assembly complete (LDPE)
05000012.2mm (.5”) – 25.4mm (1”)12.2mm (.5″) probe assembly complete: 12.2mm (.5″) diameter turbine with mirror, main body tube, 15 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″), 15.24m (50′) umbilical assembly complete (LDPE)
10000025.4mm (1”) – 31.75mm (1.25”)25.4mm (1”) probe assembly complete: 12.2mm (.5″) diameter turbine, 25.4mm (1”) centering 15 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″), 15.24m (50′) umbilical assembly complete (LDPE), adapter/flood tube with motor drive bracket
15001031.75mm (1.25”) – 50.8mm (2”)50.8mm probe assembly complete: 12.2mm (.5″) diameter turbine, 50.8mm (2”) centering device, 15 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″), 15.24m (50′) umbilical assembly complete (LDPE), adapter/flood tube with motor drive bracket
15001231.75mm (1.25”) – 50.8mm (2”)50.8m flexible probe assembly complete: 12.2mm (.5″) diameter turbine, 50.8mm (2”) flexible centering device, 15 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″), 15.24m (50′) umbilical assembly complete (LDPE), used on boiler tubes to navigate bends; no adapter/flood tube
16100063.5mm (2.5”) – 82.6mm (3.25”)88.9mm probe assembly complete: 15.8mm (.625″) diameter turbine, 88.9mm (3.5”) centering device, 15 MHz, 6.35mm (.25″) diameter, focused at 44.45mm (1.75″), 15.24m (50′) umbilical assembly complete (Nylon)
16100163.5mm (2.5”) – 82.6mm (3.25”)88.9mm flexible probe assembly complete: 15.8mm (.625″) diameter turbine, 88.9mm (3.5”) flexible centering device, 15 MHz, 6.35mm (.25″) diameter, focused at 44.45mm (1.75″), 15.24m (50′) umbilical assembly complete (Nylon), used on boiler tubes to navigate bends; no adapter/flood tube
201500All tube sizes4.57m (15′) BNC to BNC signal cable

TURBINES

IRIS turbines are propelled by water and include a 45° mirror.

Part NumberTube Range IDDescription
1040008.6mm (.34”) – 12.2mm (.5”)8.6mm complete turbine assembly with 45° mirror
10300012.2mm (.5”) – 50.8mm (2”)12.2mm complete turbine assembly with 45° mirror
10500050.8mm (2”) – 82.6mm (3.25)15.8mm complete turbine assembly with 45° mirror

ULTRASOUND TRANSDUCERS

IRIS transducers are focused immersion transducers.

Custom ultrasound transducers available in different frequencies and focal lengths.

Part NumberTube Range IDDescription
2001008.6mm (.34”) – 12.2mm (.5”)15 MHz, 5.4mm (.21″) diameter, focused at 19.05mm (.75″)
20100012.2mm (.5”) – 38.1mm (1.5”)15 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″)
20010238.1mm (1.5”) – 82.6mm (3.25”)15 MHz, 6.35mm (.25″) diameter, focused at 44.45mm (1.75″)
20010512.2mm (.5”) – 38.1mm (1.5”)20 MHz, 6.35mm (.25″) diameter, focused at 25.4mm (1″)

CENTERING DEVICES

IRIS centering devices are constructed of stainless steel (larger devices include aluminum for weight reduction).

Custom centering devices available for your application.

Part NumberTube Range IDDescription
0510508.6mm (.34”) – 12.2mm (.5”)8.6mm (.34″) main body tube
10120012.2mm (.5”) – 25.4mm (1”)Main body tube for 12.2mm (.5”) tubes and base for all size centering devices
10100025.4mm (1”) – 31.75mm (1.25”)25.4mm (1”) centering device assembly complete
15100031.75mm (1.25”) – 50.8mm (2”)50.8mm (2”) centering device assembly complete
15100131.75mm (1.25”) – 50.8mm (2”)50.8mm (2”) flexible centering device assembly complete (used on boiler tubes to navigate bends)
15150044.45mm (1.75”) – 69.85mm (2.75”)63.5mm (2.5”) flexible centering device assembly complete (used on boiler tubes to navigate bends)
16000063.5mm (2.5”) – 82.6mm (3.25”)88.9mm (3.5”) centering device assembly complete
16000163.5mm (2.5”) – 82.6mm (3.25”)88.9mm (3.5”) flexible centering device assembly complete (used on boiler tubes to navigate bends)

PROBE CABLES

IRIS umbilical cables are available in various lengths and rigidness. Most common listed here.

Custom lengths available.

Part NumberTube Range IDDescription
2020018.6mm (.34”) – 12.2mm (.5”)15.24m (50′) umbilical assembly complete (LDPE)
2020058.6mm (.34”) – 12.2mm (.5”)15.24m (50′) umbilical assembly complete (Nylon)
20200012.2mm (.5”) – 50.8mm (2”)15.24m (50′) umbilical assembly complete (LDPE)
20200250.8mm (2”) – 82.6mm (3.25”)15.24m (50′) umbilical assembly complete (Nylon)
20300012.2mm (.5”) – 82.6mm (3.25”)22.86m (75′) umbilical assembly complete (Nylon)
20310012.2mm (.5”) – 82.6mm (3.25”)30.48m (100′) umbilical assembly complete (Nylon)

ADAPTER/FLOOD TUBES

IRIS adapter/flood tubes are constructed of stainless steel (larger diameter adapters include aluminum for weight reduction).

Custom adapter/flood tubes available for your application.

Part NumberTube Range IDDescription
30002725.4mm (1”) – 31.75mm (1.25”)25.4mm (1″) adapter tube complete; used for flooding tubes, includes: locking collet and motor drive bracket
30004031.75mm (1.25”) – 50.8mm (2”)50.8mm (2″) adapter tube complete; used for flooding tubes, includes: locking collet and motor drive bracket
30151541.28mm (1.625”) – 57.15mm (2.25”)57.15mm (2.25″) adapter tube complete; used for flooding tubes, includes: motor drive bracket, does not include locking collet
30151657.15mm (2.25”) – 82.6mm (3.25”)76.2mm (3″) adapter tube complete; used for flooding tubes, includes: motor drive bracket, does not include locking collet

Related Products

IRIS Accessories

The following components are necessary to complete an IRIS inspection.